60mm stainless steel case brass connection bottom type pressure gauge 150psi oil filled pressure gauge

60mm stainless steel case brass connection bottom type pressure gauge 150PSI oil filled pressure gauge

Quick Details


Name: Stainless Oil Filled Pressure Gauge
Accuracy class: 0.1C, 0.1
Temperature range: 0-2kg/cm3
Work temperature: -40-70C
connection thread: BSP, NPT, BSPT and other special specifications
liquid: glycerin or silicone
material: stainless steel case and brass internal
Dial diameter: 60mm
Certification: CE ROHS
Connector: stainless steel,brass

Product Description


1. Grade: SUS201,SUS304,SUS316
2. Size: YN100 3/8PT
3. Standard: DIN 315
4. Certification: ISO9001, SGS, CTI, ROHS

Pressure gauge (English name: pressure gauge) refers to an elastic element is a sensitive element, indicating higher than ambient pressure measurement and instrumentation, application is very common, it is virtually all industrial processes and scientific fields. In the field of heat pipe, oil and gas transmission, water supply system, vehicle maintenance factory shops everywhere. Especially in the industrial process control and measurement technology process, due to the elastic sensing element mechanical pressure gauge with high mechanical strength and ease of production, which makes the mechanical pressure gauge to be more widely used.

 

Caution


1, the instrument must be vertically: the installation should use 17mm wrench tightened
Strong case should not be twisted; transport should avoid the collision;
2, the instrument should be in use ambient temperature of -25 ~ 55 ℃;
3, the use of the work environment vibration frequency <25HZ, the amplitude is not greater than 1mm;
4, due to the use of ambient temperature is too high, the instrument indicated value does not return to zero or appears showing the value of tolerance, upper case can cut the rubber plugs, the instrument can be cavity with the atmosphere;
5, the use of the instrument should be the upper limit of 1/3 to 2/3 between;
6, in the measurement of corrosive media, the media may crystallize, viscosity of the medium should be added isolation device;
7, the instrument should be regular checks (at least once every three months), found fault should be repaired;
8, the date of delivery of the instrument since, if within six months due to poor manufacturing quality failure or damage under normal storage conditions of use found by the company responsible for the repair or replacement;
9, corrosive media measurement instrumentation required in the order shall specify the required condition.

Favorable Comment


(1) Working temperature should not exceed 80 ℃, if the steam directly into the table, is likely to cause failure of the gauge, and therefore at the beginning, it must make the connection table elbow memory full of water, the water used in the state after confirmation elbow memory.

(2) In the following heating stove gauge, install a three-way tap, tap handle axial direction and connected to a tube
It should be opened for the cause.

(3) When the gauge is placed farther away from the drum, and the use of longer connecting tube in place is necessary to set up near the drum a sectional door. In this case, you should cut back doors open or locked or the handle removed.

(4) pressure gauge and its connection, when not used for a long time, and no proper storage, prior to use to pay attention Bends and connecting pipe purge to remove rust class booty. Such as when attached scale, completely remove or replace.

(5) In the winter, when there is a long time off the risk of freezing, the pressure gauge should remove custody, the connecting elbow Water within the drain.

(6) usually should be prepared to experience a good gauge to check spare, there is a problem when the gauge was found in the operation,It should be ready to close the connection tube cock, put spare compare inspection. Pressure gauge is not required to wait until the malfunction
When replacing, but after a certain period of time to check and replace spare table. Rules of order, pressure gauges installed after each use check at least once half a year, it should be sealed after calibration.

, , , , ,