Quick Details
Title: GPT210 Food Flush Diaphragm pressure transmitter
Pressure range: 0~35kPa...20MPa
pressure type: gauge (G), absolute (A), sealed gauge (S)
verpressure: 150%FS or 110MPa(min. value is valid)
output signal: 4~20mA 0~5Vdc 1~5Vdc 0~10Vdc 0.5~4.5Vdc
0~10Vdc 0.5~4.5Vdc power supply: 15~28V
electrical interface: DIN43650
material of pressure membrane: 316L stainless steel
Customized: Accpetable
OEM: Acceptable
Product Description
GPT210B pressure transmitter adopts GS series piezoresistive flat membrane silicon oil-filled sensing element as the signal measuring element, the signal processing circuit is built-in of the stainless steel housing The sensor s output signal is transferred to standard element, the signal processing circuit is built-in of the stainless steel housing The sensor s output signal is transferred to standard output signal Its output signal can be made standard voltage output signal,or,current output signal,or frequency output signal This product is made with flush membrane structure clamping type It has good ability on preventing fouling,crystallization and jamming of thick liquids.
Feature
pressure range: 0~35kPa...3.5 MPa
gas or dilute liquid compatible with 316LSS
high reliability and stability
Applications:
process control system
medical
biological products
food hygiene
Product Parameter
Name | Data | |||||
Pressure range | 0~35kPa...3.5MPa | |||||
pressure type | gauge (G), absolute (A), sealed gauge (S) | |||||
Overload pressure | 150%FS or 110MPa(min. value is valid) | |||||
Accuracy | 0.25%FS(typ.) ±0.5%F.S | |||||
long-term stability | ≤0.3%FS/year | |||||
temp.coefficient of zero | ±0.02%FS/°C(typ.) ±0.03%FS/°C(max.) | |||||
temp.coefficient of span | ±0.02%FS/°C(typ.) ±0.03%FS/°C(max.) | |||||
Operating temperature | -20°C~80°C | |||||
compensate temperature | 0°C~70°C | |||||
storage temperature range | -40°C~120°C | |||||
Medium compatibility | All corrosive medium compatible with 1Cr18Ni9Ti | |||||
Electrics feature | Two-wire type | Three-wire type | ||||
Output signal | 4~20mA | 0~5V | 1~5V | 0~10V | ||
Power supply | 15~28Vdc | 15~28Vdc | 15~28Vdc | 15~28Vdc | ||
Load resistance | R≤(U-15)/0.02 (for 4/20mA) | R>100kΩ(for votage output) | ||||
Insulating resistance | >100M Ω@100V | |||||
electrical interface | DIN43650 | |||||
pressure interface | M20x1.5,G1/2 (customer request) | |||||
material of pressure membrane | 316L stainless steel | |||||
material of housing | 1Cr18Ni9Ti stainless steel | |||||
response time(10%~90%) | ≤10ms | |||||
shock/impact | 10gRMS,(20~2000)Hz / 100g,11ms | |||||
protection | IP65 |
Attention
1. Product shall not be used to test mediums that not compatible with stainless steel;
2. Make sure power supply is conformed with power requirements of the probe, and positive and negative wiring connection correct. Ensure max pressure of the medium is in range of the product capacity;
3. During measurement, please exert or release the pressure slowly to prevent a high or low pressure occurred
in very short time;
4. In case of medium spout, disconnect the pressure source before probe disassembly.
5. To avoid damage caused by misusage, please DO NOT disassemble the product or touch the diaphragm.